PeptidePedia The community reference

Third-party testing: difference between revisions

Diff·revision 4 → 5·13:40, 25 Jul 2024

Difference between revision 4 and revision 5 of Third-party testing. 4 lines changed; the page grew by 535 bytes.

Revision 4 — 21:08, 16 Jul 2024
SupplyWatchSuri (talk)
split overlong sentence
1,906 bytes ±0
Revision 5 — 13:40, 25 Jul 2024
Peptide_Pete (talk)
correct the description of how lot identifiers are assigned
2,441 bytes +535
15Three separate questions are involved and are routinely collapsed into one.15Three separate questions are involved and are routinely collapsed into one.
1616
+17# ''Is this sample what it claims to be?'' Answered by identity determination — [[Mass spectrometry|mass confirmation]] against the calculated mass, ideally with sequence-level confirmation. A purity figure alone does not answer it.
+18# ''How pure is this sample?'' Answered by chromatographic purity, which is an area-normalised figure and not a mass.
+19# ''How much active substance is in the vial?'' Answered only by [[Peptide content|peptide content]] together with a water determination and a fill mass. Purity does not answer it.
+20
17== References ==21== References ==
18{{reflist}}22{{reflist}}