| Revision 4 — 21:08, 16 Jul 2024 SupplyWatchSuri (talk) split overlong sentence 1,906 bytes ±0 | Revision 5 — 13:40, 25 Jul 2024 Peptide_Pete (talk) correct the description of how lot identifiers are assigned 2,441 bytes +535 | ||
|---|---|---|---|
| 15 | Three separate questions are involved and are routinely collapsed into one. | 15 | Three separate questions are involved and are routinely collapsed into one. |
| 16 | 16 | ||
| + | 17 | # ''Is this sample what it claims to be?'' Answered by identity determination — [[Mass spectrometry|mass confirmation]] against the calculated mass, ideally with sequence-level confirmation. A purity figure alone does not answer it. | |
| + | 18 | # ''How pure is this sample?'' Answered by chromatographic purity, which is an area-normalised figure and not a mass. | |
| + | 19 | # ''How much active substance is in the vial?'' Answered only by [[Peptide content|peptide content]] together with a water determination and a fill mass. Purity does not answer it. | |
| + | 20 | ||
| 17 | == References == | 21 | == References == |