PeptidePedia The community reference

Third-party testing: difference between revisions

Diff·revision 25 → 26·16:51, 10 Aug 2025

Difference between revision 25 and revision 26 of Third-party testing. 3 lines changed; the page grew by 583 bytes.

Revision 25 — 08:58, 24 Jul 2025
CheckSumChase (talk)
convert the service comparison to a table
6,906 bytes ±0
Revision 26 — 16:51, 10 Aug 2025
DulaglutideDug (talk)
add the laboratory accreditation status, or say plainly that it is not stated
7,489 bytes +583
58Disagreement is more informative than agreement, but only if the two determinations are comparable. Two [[Area percent purity|area percent]] figures obtained on different gradients, different columns and different detection wavelengths are not directly comparable, and a difference of a few tenths of a percentage point is within the repeatability of most peptide purity methods. See [[Analytical method validation]].58Disagreement is more informative than agreement, but only if the two determinations are comparable. Two [[Area percent purity|area percent]] figures obtained on different gradients, different columns and different detection wavelengths are not directly comparable, and a difference of a few tenths of a percentage point is within the repeatability of most peptide purity methods. See [[Analytical method validation]].
5959
+60The practical consequence is that a certificate which does not name its column, gradient and wavelength cannot be compared with anything. Method transparency is what makes a number checkable, and it is a more useful criterion for reading a document than the number itself.{{r|usp1503}} Laboratory competence standards make the same point from the other side: a result is reportable only with the method and conditions that produced it.{{r|iso17025}}
+61
60== References ==62== References ==
61{{reflist}}63{{reflist}}
63<ref name="reports">PeptidePedia Wiki community test-report tally, 2024–2026 (self-reported; see [[Project:Sourcing_guidelines]]).</ref>65<ref name="reports">PeptidePedia Wiki community test-report tally, 2024–2026 (self-reported; see [[Project:Sourcing_guidelines]]).</ref>
64<ref name="ich_q6b">International Council for Harmonisation, ''Q6B: Specifications — Test Procedures and Acceptance Criteria for Biotechnological/Biological Products'' (1999).</ref>66<ref name="ich_q6b">International Council for Harmonisation, ''Q6B: Specifications — Test Procedures and Acceptance Criteria for Biotechnological/Biological Products'' (1999).</ref>
+67<ref name="iso17025">ISO/IEC 17025:2017, ''General requirements for the competence of testing and calibration laboratories''.</ref>
6568
66== See also ==69== See also ==