| + | 33 | The figures are illustrative of the shape of the relationship rather than exact, and the exact values follow from the binomial distribution and the sampling plan. The point is that end-product sterility testing detects gross failure reliably and low-level failure poorly, which is why it functions as a final check on a validated process rather than as the basis for release on its own.{{r|usp1211}} | |