correct the flow rate — the source gives it in mL/min
4,001 bytes ±0
Revision 16 — 15:53, 12 Jul 2025
ColumnOvenCoy (talk)
add the peptide-content point: area percent alone cannot give a mass
4,550 bytes +549
33Research-chemical certificates rarely state any of these, which is why "no other peaks observed" is uninformative without the method behind it. The statement may reflect a clean material or a method with a high detection limit, and nothing in the document distinguishes the two.{{r|usp1503}}33Research-chemical certificates rarely state any of these, which is why "no other peaks observed" is uninformative without the method behind it. The statement may reflect a clean material or a method with a high detection limit, and nothing in the document distinguishes the two.{{r|usp1503}}
3434
+35== Practical consequences ==
+36Two certificates reporting different numbers of impurities may describe identical material analysed by methods of different sensitivity. The one listing more impurities is not describing worse material; it may simply be looking harder.{{r|ich_q2}}
+37
+38This inverts the naive reading. An itemised related-substances table listing six impurities at 0.05–0.2% is evidence of a sensitive method and a transparent report; a certificate stating "purity 99.9%, no other peaks" may be evidence of a method that cannot see them.
+39