PeptidePedia The community reference

Haemoglobin A1c (revision 22)

Old revision·19:57, 7 Feb 2026·SurpassSunniva

This is an old revision of this page, as it stood at 19:57, 7 Feb 2026, saved by SurpassSunniva with the summary attribute the population interval to the cohort it was derived from. It may differ substantially from the current revision, and any error it contains may since have been corrected.
Haemoglobin A1cLaboratory medicine
AbbreviationHbA1c
ReflectsAverage glucose over ~8–12 weeks
Unitsmmol/mol (IFCC); % (DCCT/NGSP)
Confounded byAnything altering red-cell lifespan
Topic infobox · conventions

Haemoglobin A1c is the fraction of haemoglobin that has been non-enzymatically glycated. Because glycation is irreversible and proceeds at a rate proportional to glucose concentration, the fraction integrates glucose exposure over the lifespan of the circulating red cells — roughly the preceding eight to twelve weeks, weighted towards the more recent.[1]

It is reported in two unit systems: mmol/mol under the IFCC reference method, and percentage under the older DCCT-aligned convention. Both appear in the literature and conversion between them is defined.[2]

Its principal limitation follows from its mechanism: anything that alters red-cell lifespan alters the result independently of glucose. Haemolysis and blood loss lower it; iron deficiency and reduced turnover raise it.[1]

What it measures

[edit]

Glycation is a slow non-enzymatic reaction between glucose and the N-terminal valine of the haemoglobin β-chain. Its extent depends on both glucose concentration and exposure time, and because red cells are replaced continuously the population of cells sampled at any moment carries a weighted history.[2]

The weighting is not uniform: roughly half the value reflects the preceding month, and the remainder the two months before. A change made three weeks ago is therefore only partly expressed.[1]

Estimated average glucose can be derived from HbA1c by a published regression, and the derivation carries substantial individual variation — two people with identical HbA1c can have appreciably different mean glucose.[2] The measure is a laboratory determination with its own method dependence, as any determination is.[3]

Confounders

[edit]
ConditionDirection
Haemolysis, blood loss, transfusionLower
Iron or B12 deficiencyHigher
Chronic kidney diseaseVariable
Haemoglobin variantsAssay-dependent interference
PregnancyLower, from increased turnover

Haemoglobin variants interfere with some assay methods and not others, so a discrepancy between HbA1c and other glycaemic measures should prompt a question about the method rather than an assumption about glucose.[1]

Where HbA1c is unreliable, fructosamine or continuous glucose monitoring metrics provide alternatives measuring different windows.[2]

Use in this field

[edit]

HbA1c is the primary glycaemic endpoint in essentially every type 2 diabetes trial discussed on this wiki, including the SUSTAIN and SURPASS programmes. Reductions of 1–2.5 percentage points are the range these agents produce.[4]

Because the measure integrates over months, a trial cannot demonstrate a glycaemic effect faster than the analyte can move, which is why glycaemic trials run at least six months.[1]

It appears on most of the panels discussed in this field; see Baseline laboratory panel. Nothing on this wiki is medical advice.[1]

See also

References

  1. ^ a b c d e f American Diabetes Association. "Standards of Care in Diabetes." Diabetes Care 47(Suppl 1) (2024).
  2. ^ a b c d Nathan DM, Kuenen J, Borg R, et al. "Translating the A1C assay into estimated average glucose values." Diabetes Care 31(8):1473–1478 (2008). PMID 18540046.
  3. ^ United States Pharmacopeia, General Chapter <1503>, Quality Attributes of Synthetic Peptide Drug Substances.
  4. ^ Drucker DJ. "Mechanisms of action and therapeutic application of glucagon-like peptide-1." Cell Metabolism 27(4):740–756 (2018). PMID 29617641.